Protecting Legerity Subscriber Line Interface Circuits for Intra-building protection solution
Projeto de referência por: Bourns
GR-1089-CORE intra-building has a 100A 2/10 us test where the equipment must work after the test. The TISP9110LDM has a 2/10 us capability of 100A that helps ensure intra-building impulse requirements are achieved without the need of additional series resistance