Power Monitoring for Instrumentation

參考設計 屬於: Analog Devices

Power Monitoring for Instrumentation
Application circuit delivers constant power to a varying load. Using a load-monitoring IC (MAX4210), it senses the load current and load voltage independently, and multiplies the corresponding signals together with an internal analog multiplier. Applying the multiplier output to the inverting input of an error amplifier lets you apply a control voltage to set the constant-power level