LDF4-50A, HELIAX® Low Density Foam Coaxial Cable, corrugated copper, 1/2 in, black PE jacket Halogen free jacketing non-fire-retardant (General propose cable for outdoor use only)
Commscope LDF4-50A technical specifications.
| Product Type | Coaxial wireless cable |
| Product Brand | HELIAX® |
| Product Series | LDF4-50A |
| Ordering Note | ANDREW® standard product (Global) |
| Product Number (internal) | 520094002/00 | SZ520094902/00 |
| Flexibility | Standard |
| Jacket Color | Black |
| Performance Note | Attenuation values typical, guaranteed within 5% |
| Diameter Over Dielectric | 12.954mm |
| Diameter Over Dielectric | 0.51in |
| Diameter Over Jacket | 15.875mm |
| Diameter Over Jacket | 0.625in |
| Inner Conductor OD | 4.826mm |
| Inner Conductor OD | 0.19in |
| Outer Conductor OD | 13.97mm |
| Outer Conductor OD | 0.55in |
| Nominal Size | 1/2in |
| Cable Impedance | 50ohm ±1 ohm |
| Capacitance | 75.8pF/m |
| Capacitance | 23.104pF/ft |
| dc Resistance, Inner Conductor | 1.48ohms/km |
| dc Resistance, Inner Conductor | 0.451ohms/kft |
| dc Resistance, Outer Conductor | 2.69ohms/km |
| dc Resistance, Outer Conductor | 0.82ohms/kft |
| dc Test Voltage | 4000V |
| Inductance | 0.19μH/m |
| Inductance | 0.058μH/ft |
| Insulation Resistance | 100000MOhms-km |
| Jacket Spark Test Voltage (rms) | 8000V |
| Operating Frequency Band | 1–8800MHz |
| Peak Power | 40kW |
| Velocity | 88% |
| Dielectric Material | Foam PE |
| Jacket Material | PE |
| Inner Conductor Material | Copper-clad aluminum wire |
| Outer Conductor Material | Corrugated copper |
| Minimum Bend Radius, multiple Bends | 127mm |
| Minimum Bend Radius, multiple Bends | 5in |
| Minimum Bend Radius, single Bend | 50.8mm |
| Minimum Bend Radius, single Bend | 2in |
| Number of Bends, minimum | 15 |
| Number of Bends, typical | 50 |
| Tensile Strength | 113kg |
| Tensile Strength | 249.122lb |
| Bending Moment | 3.8N-m |
| Bending Moment | 33.633in lb |
| Flat Plate Crush Strength | 2kg/mm |
| Flat Plate Crush Strength | 111.995lb/in |
| Installation temperature | -40 °C to +60 °C (-40 °F to +140 °F) |
| Operating Temperature | -55 °C to +85 °C (-67 °F to +185 °F) |
| Storage Temperature | -70 °C to +85 °C (-94 °F to +185 °F) |
| Attenuation, Ambient Temperature | 68°F |
| Attenuation, Ambient Temperature | 20°C |
| Average Power, Ambient Temperature | 104°F |
| Average Power, Ambient Temperature | 40°C |
| Average Power, Inner Conductor Temperature | 212°F |
| Average Power, Inner Conductor Temperature | 100°C |
| Cable weight | 0.22kg/m |
| Cable weight | 0.148lb/ft |
| Attenuation (dB/100m) at 1.0 MHz | 0.211dB/100m |
| Attenuation (dB/100m) at 8800.0 MHz | 25.244dB/100m |
| Average Power (kW) at 1.0 MHz | 36.11kW |
| Average Power (kW) at 8800.0 MHz | 0.3kW |
| Military Spec | False |
| Cenelec | EN 50575 compliant, Declaration of Performance (DoP) available |
| China-rohs | Below maximum concentration value |
| Iso 9001:2015 | Designed, manufactured and/or distributed under this quality management system |
| Reach-svhc | Compliant as per SVHC revision on www.andrew.com/ProductCompliance |
| RoHS | Compliant |
| Uk-rohs | Compliant |
Download the complete datasheet for Commscope LDF4-50A to view detailed technical specifications.